Bhanu Scientific Glass Co.

ASSEMBLIES OVER GLASS LINED REACTOR

Glass Lined Reactors are used instead of glass reactors especially when the scale of operation is large and relatively high-pressure steam is to be used as heating media.

Quite often assemblies like Simple Distillation Unit, Reaction Distillation Unit, Fractional Distillation Unit etc. are installed above glass-lined reactors.

The basic features of these assemblies remain the same but glass shell and tube heat exchanger are preferred due to the large scale of operation.

A typical fractional distillation unit type assembly over GLR is shown in the adjacent figure.

The standard overhead glass assemblies on GLR’s (Glass Lined Reactors) are designed for reactions under reflux and distillation.

The Standards Process Equipment are:

  • Spherical / Cylindrical Graduated Feed Vessels for controlled addition of Liquid Reactants.
  • Vapour Column – Packed or Hollow
  • Primary Condenser – Coil Type Glass Heat Exchanger or Shell & Tube Type Heat Exchanger.
  • Vent or Secondary Condenser
  • Product Cooler – For cooling distillate
  • Phase Separators – For multi-component distillation or Azeotropic Distillations
  • Distillate Receivers for continuous operation without breaking of Vacuum
  • Pressure Equalisation ensured by process pipeline design being to maintain complete hydraulic integrity and single point application of vacuum over the complete system.

Objects :

  • Various options for which our system can be adapted are shown in figure 1, 2, 3, 4.
  • Stainless Steel / Glass , GL Bottom Pan with Glass Top Constructions.
  • Suitable for installation in Fume Hoods.
  • Skid mounted mobile unit also.

Suggested Configurations

Reactor (AE)Heat Exchange
Area (m2)
Shell & Tube Heat
Exchanger_Glass
(m2)
Shell & Tube Heat
Exchanger_Sic
(m2)
Vent Condenser
Glass (m2)
Feed Vessel
(Lit)
Receiver Vessel
(Lit)
Vapour Line
(DN)
630.532.50.3202×2080
1000.852.50.6502×5080
1601.234.01.0502×5080
2501.665.01.01002×10080
4002.408.02.51.01002×100100
5002.568.02.51.51002×100150
6303.1010.03.21.51002×100150
10004.5612.54.01.52002×200200
16006.0016.05.01.52002×200200
20007.1016.05.01.52002×200200
25008.3020.06.31.52002×200200
30009.1020.06.31.52002×200200
400011.7025.08.01.52002×200200
500013.1025.08.02.52002×200300
630016.2025.08.04.02002×200300

Typical Overhead Glass Assembly For GLR

GLASS OVERHEAD ASSEMBLYFOR GLR

Assemblies Over Glass Lined Reactor (GLR) for industrial applications. High-efficiency, corrosion-resistant, and customizable solutions
Assemblies Over Glass Lined Reactor (GLR) for industrial applications. High-efficiency, corrosion-resistant, and customizable solutions
Assemblies Over Glass Lined Reactor (GLR) for industrial applications. High-efficiency, corrosion-resistant, and customizable solutions
Assemblies Over Glass Lined Reactor (GLR) for industrial applications. High-efficiency, corrosion-resistant, and customizable solutions
Scroll to Top